 Care and Use information

             click to return to ThermALP product sheet

Automated Use:

Edit the plate ALP height for the location at which the ThermALPÔ resides in the BFX software.

You can also do this by increasing the Plate definition height Z + ~11.00 mm. Seating depth of various plate types varies.

Dimensions: (Relative to a Static ALP)

Additional ALP Height: ………..11.8 mm

Overall Plate Height:…………….165mm

Specifications: Thermal

Maximum temperature = 65° C ( Osha Limit, tested to 90° C)

Minimum temperature = -0° C ( limited by chiller low limit)

  • Minimum operating temperature is dependent on the recirculating refrigerator lower capability.

Installation: Do not loosen or remove any of the sealed fittings or plugs.

Disassemble the ALP completely. If needed mount the friendly points from the old ALP to the ThermALPÔ or mount the thermal collars purchased with your device Thread 4 nylon 6-32 screws down through the ThermALPÔ at the corners. Install the nylon washers over the bottom and assemble the rods into the threads with the nylon washers. Mount the ALP base back onto the new ALP assembly. The recirculating chiller connections are as follows: Cut the ¼ " tubing between the device and the Recirculator. Flow direction is not critical. Locate the ALP in a location that it will not encounter any obstructions. Condensate will build up on the tubing, route accordingly. Typically up to 3 units can be ganged together on one recirculator in a parallel arrangement.

Operation: recirculating refrigerator bath.

Use a 60% glycol mixture in the recirculator reservoir. Allow the recirculator to reach the setpoint temperature, ~30 minutes for the Low side. It is best to measure the temperature right at the plate with a non-contact thermometer if the control is critical. You can also use a condensate wrap or insulation around the perimeter if required. It Is best if the unit does not remain on at less than freezing temperatures for periods greater than 24 hours, as frost will build up and may affect plate positioning. If you encounter any difficulty with this integration contact: Jeff Cahlik @ (423) 452 0893 9-4pm EST.

 

 